Appendix 3. PLC Development Environment using GPPQ
3.5.4 Ladder Comparison with the C64 Controller
The method of comparing the ladders between the C64 controller and GPPQ is explained below.
(1) Menu Selection
The screen is selected from the menu using the following GPPQ basic operation.
Alt
Mode screen
(2) Screen Operation
The file names are designated and executed on the following screen. The options that can be
selected are the same as those of the ladder read.
File name designation method
Input the file name stored in the read target memory.
Display the read target memory list screen by pressing Ctrl + D .
Display the file list screen by pressing Ctrl + L .
After selecting the file using ↑ and ↓ , display the file name selected in the file name
designation column by pressing Enter .
[PC compare]
Interface
Target PC
Target Mem
1. File 1. File Name [
2. Tgt
:
:
:
When the comparison contents do not match, a screen with the mismatched contents
appears.
[Sequence Program Diff List]
Step
15
18
22
PgDn : Next page
3.5 PLC Program Development Procedure
PC menu
( GRPH )
2
window
Menu
PC
RS232C
<--->
QnACPU
Network : 0
Station : FF
Internal RAM
Title [
]
Title [
1. [ * ] Parameter
Execute(Y)
Ctrl+L : filelist Ctrl+D : directo Space : sele Esc : close
<Memory>
Ins
I/O
AND= R4918
K106
+
R4916
K10000
D87
END
No Data exists.
No Data exists.
- 449 -
Get other manuals https://www.bkmanuals.com
PC compare
3
screen
Compare
PC Type : Q4A
Cancel(N)
<PC>
Step
Ins
I/O
15
NOP
16
NOP
17
NOP
18
+
R4916
K10000
D87
22
END
Esc : Close
]
]