Mitsubishi Electric MELDAS C6 Programming Manual page 39

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

1. PLC Development Environment Using GX Developer
(2) Description Method
The message data is described as text data by the following description format.
;# ladder ver1. '00.08.01
;$, A,32, 200
;$, 0, 40, 200
;$, P, 14, 32
;$, M, 60, 20
NOPLF
;A, 0, 0, Emergency stop
;A, 11, 1, Spindle alarm
:
:
NOPLF
:
:
NOPLF
:
:
NOPLF
;0, 1, 9000, MELDAS 600LADDER Ver1.0
;0, 20, 9000, BND-400W000-A0
:
:
NOPLF
;P, 1, Program restart
;P, 2, Automatic power OFF
:
:
NOPLF
;M, 1, 0, [Spindle]
;M, 1, 0, [Standby 1]
:
:
END
(a) Comment
Statements having a semicolon (;) at the head of the line, in a different format than described in
"(1) Description format", are regarded as comments. These comments are handled as
comment data in the GX Developer also, but are erased during the transfer to the CNC
controller. An error will occur if there is no semicolon at the head of the line.
(b) Setting area
Each message is set here. This area must be described before the message area of the
relevant message. That setting will be ignored if it is described in the middle of or after the
relevant message description.
(c) Message area
Collect similar messages in a group and describe them. There is no description order in the
respective messages, but the latter description is validated if there are descriptions with the
same factors (index No., etc.).
(d) Page break code
A page break code is described at one or more places approx. every 15 lines in the setting area
and message area. The message data may skip if there is no page break code.
1.4 Creating PLC-related Data
- 30 -
Get other manuals https://www.bkmanuals.com
... Comment
... Setting area
... Message area (alarm messages)
... Page break code
... Message area (operator messages)
... Message area (PLC switches)
... Message area (comments)
... End code