Mitsubishi Electric MELDAS C6 Programming Manual page 307

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

BSET, BSETP ... Bit setting of word device
Bit device
X
Y M
L
F
B SB T SM V T
D
n
BSET
BSETP
Function
(1) The bit n of the word device designated with D is set to 1.
(2) The value 0 to 15 can be designated for n.
If n exceeds 15, the command is executed is executed with the low-order 4 bits data.
D10 before execution
D10 after execution
8. Function Commands
BSET, BSETP
Usable device
Word device
C D R W SW Z SD K
Bit set command
BSETP
BSETP
BSETP
b15
b15
実行前
1 1 0 0 1 0 1 1 0 0 1 1 1 0 1 1
D10
1 1 0 0 1 0 1 1 0 0 1 1 1 0 1 1
b15
b15
実行後
D10
1 1 0 0 1 0 1 1 0 1 1 1 1 0 1 1
1 1 0 0 1 0 1 1 0 1 1 1 1 0 1 1
- 298 -
Get other manuals https://www.bkmanuals.com
Con-
Pointer
stant
H
P
BSET
D
D
BSETP
Setting data
No. of device to set
D
the bit.
Bit No. to be set.
n
D10
K6
D10
D10
K6
K6
b1b0
b6
b6
b1
b0
b1b0
b6
b6
b1
b0
1になります。
Becomes "1"
Digit
No. of
desig-
Index
steps
nation
2
n
n