Program example
(1) Program to average the details of D882 to D888 when XB turns ON, and to output the results to
D0.
XB
10
7 data items
(Note) Fractional values are omitted.
8. Function Commands
S.AVE
S.AVE
D882
D0
K7
D882
123
D883
10
D884
500
D885
123
D886
20
D887
123
D888
123
Averaging of data with S.AVE command
- 291 -
Get other manuals https://www.bkmanuals.com
Coding
No. of
Com-
Device
steps
mand
10
LD
XB
11
S.AVE D882
16
Average value
D0
146
D0
K7