AND, ANI ... Serial connection of contact
Bit device
X
Y
M
L
F
B SB T SM V T
(Note) In the modification of index, 2 steps are used for B or SB device.
AND
ANI
Function
AND is the A contact serial connection command, and ANI is the B contact serial connection
command. The ON/OFF information of the designated device is read in, and the AND operation with
the operation results up to that point is executed. The result is the operation result.
Execution conditions
This is executed per scan regardless of the operation results before the AND, ANI commands.
7. Basic Commands
AND, ANI
Usable device
Word device
C D R W SW Z SD K
X0
X0
- 106 -
Get other manuals https://www.bkmanuals.com
Digit
Con-
Pointer
desig-
stant
nation
H
P
Device No.
No. of
Index
steps
1/2