INC, INCP ... (16-bit BIN data) +1
Bit device
X
Y M
L
F
B SB T SM V T
D
IN C
INCP
Function
(1) The device (16-bit data) designated with D is incremented by one.
B15.................................B0
5678 (BIN)
(2) If INC or INCP is executed when the data of the device designated with D is 32767, -32768 will be
stored in the device designated with D.
Execution conditions
The execution conditions for the INC, INCP commands are as shown below.
Command OFF
IN C
INCP
8. Function Commands
INC, INCP
Usable device
Word device
C D R W SW Z SD K
Increment command
IN C
INCP
D
+1
ON
Executed per scan
- 186 -
Get other manuals https://www.bkmanuals.com
Con-
Pointer
stant
H
P
D
Setting data
No. of device to be
D
incremented (+1)
D
D
B15.................................B0
5679 (BIN)
Executed per scan
Digit
No. of
desig-
Index
steps
nation
2