Mitsubishi Electric MELDAS C6 Programming Manual page 133

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

OUT (C) ... Counter output
Bit device
X Y M L F B SB T SM V T C D R W SW Z SD K H
Device
Setting
value
Function
(1) If the operation results before the OUT command change from OFF to ON, the current value
(count value) will be incremented by one. When the value is counted up (current value >= setting
value), the contacts will change as shown below.
A contact
B contact Non-continuity
(2) The value will not be counted when the operation results are ON. (A pulse change is not required
to input the count.)
(3) If the operation results change from OFF to ON after the current value >= setting value is
established, the contact state will remain the same and the current value will not be counted up.
Execution condition
This is executed per scan regardless of the operation results before the OUT command.
7. Basic Commands
OUT (C)
Usable device
Word device
Continuity
- 124 -
Get other manuals https://www.bkmanuals.com
Digit
desig-
nation
Con-
Pointer
stant
P
Setting value
(1 to 32767 is valid)
C0 K50
Device No.(C0 to 127)
Setting value
(1 to 32767 is valid for
C1 D10
the data register details)
Device No.(C0 to 127)
No. of
Index
steps
3

Advertisement