Mitsubishi Electric MELDAS C6 Programming Manual page 211

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

BIN, BINP ... BCD
Bit device
X
Y M
L
F
B SB T SM V T
S
D
BIN
BINP
Function
The BCD data (0 to 9999) of the device designated with S is BIN converted and transmitted to the
device designated with D.
S side BCD 9999
D side BIN 9999
(Note 1) If the data designated by S is not within 0 to 9999, it will not be converted correctly.
Execution conditions
The execution conditions for BIN, BINP are as follow.
Conversion command OFF
BIN
BINP
8. Function Commands
BIN, BINP
BIN conversion (16-bit)
Usable device
Word device
C D R W SW Z SD K
BIN conversion command
BIN
BINP
8000 4000 2000 1000 800 400
1
0
0
1000th place
32768 16384 8192 4096 2048 1024 512
0
0
1
Set to 0
ON
Executed per scan
- 202 -
Get other manuals https://www.bkmanuals.com
Con-
stant
Setting data
S
D
BCD data or No. of device
S
where BCD data is stored.
No. of device to store
D
BIN data
S
D
200
100
80
40
1
1
0
0
1
1
0
100th place
10th place
BIN conversion
256
128
64
0
0
1
1
1
0
0
Executed per scan
Digit
No. of
Pointer
desig-
Index
steps
nation
H
P
20
10
8
4
2
1
0
1
1
0
0
1
1st place
32
16
8
4
2
1
0
0
1
1
1
1
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64

Table of Contents