RST ... Device resetting
Bit device
X
Y
M
L
F
B SB T SM V T
D
(Note) In the modification of index, 2 steps are used for B or SB device.
2 steps are used for T or C device, also.
Reset command
Function
(1) The designated device will change as explained below when the RST input turns ON.
Device
Y, M, L, SM, F The coil and contact are turned OFF.
T, C
(2) If the RST input is OFF, the state of the device will not change.
Execution condition
The execution conditions for the RST command are as shown below.
RST input
RST
7. Basic Commands
RST
Usable device
Word device
C D R W SW Z SD K
Status
0 is set for the current value, and the coil and
contact are turned OFF.
ON
OFF
Executed per scan
- 128 -
Get other manuals https://www.bkmanuals.com
Con-
Pointer
stant
H
Setting data
RST
D
D
Executed per scan
Digit
No. of
desig-
Index
steps
nation
P
1/2
Device No. to
be reset

Advertisement