PLS, PLF ... Pulse (1 scan ON)
Bit device
X
Y
M
L
F
B SB T SM V T
D
PLS
PLF
Function
PLS
(1) The designated device is turned ON for one scan when the PLS command changes from OFF to
ON and is turned OFF in all other cases.
X5
(2) Even if the sequence program is changed from RUN to STOP and then RUN after the PLS
command is executed, the PLS command will not be executed. If the PLS command is ON when
the power is turned ON, the PLS command will be executed.
PLF
(1) The designated device is turned ON for one scan when the PLF command changes from ON to
OFF and is turned OFF in all other cases.
X5
(2) Even if the sequence program RUN switch is changed from RUN to STOP and then RUN after
the PLF command is executed, the PLF command will not be executed.
7. Basic Commands
PLS, PLF
Usable device
Word device
C D R W SW Z SD K
PLS command
PLF command
PLS
M0
X5
OFF
M0
OFF
PLF
M0
X5
OFF
M0
OFF
- 132 -
Get other manuals https://www.bkmanuals.com
Digit
Con-
Pointer
desig-
stant
nation
H
P
PLS
D
Setting data
Device No. to
D
be pulse coded
PLF
D
ON
ON
1 scan
1 scan
ON
ON
1 scan
No. of
Index
steps
2
1 scan