Mitsubishi Electric MELDAS C6 Programming Manual page 182

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

Execution conditions
The execution conditions for D*, D*P are as shown below.
Multiplication command
D *
D*P
Program example
(1) Program to multiply the D7, 8 BIN data and D18, 19 BIN data when X5 turns ON, and output the
results to D1 to 4.
X5
10
(2) Program to multiply the D20 BIN data and D10 BIN data when X0 turns ON, and output the
high-order 16-bit to Y30 to 4F.
X0
10
8. Function Commands
D*, D*P
ON
OFF
Executed per scan
D *
D7
D18
D1
D *
D20
D10
D0
K8Y30
DMOV
D3
- 173 -
Get other manuals https://www.bkmanuals.com
Executed per scan
Coding
No. of
Com-
Device
steps
mand
10
LD
X5
11
D*
D7
16
Coding
No. of
Com-
Device
steps
mand
10
LD
X0
11
D*
D20
D10
16
DMOV D3
K8Y30
19
D18
D1
D0

Advertisement