User Group - Mitsubishi Electric Evolution+ s-MEXT Technical Manual

Table of Contents

Advertisement

2.6.3

User Group

Par.N.
30.01
Supervision presence configuration
30.02
BMS address configuration
BMS protocol configuration (0:Standard – 1:Modbus – 2:GSM Modem –
30.03
3:LON – 4:Bacnet – 5:TCP/IP – 6:WinLoad)
BMS baud rate configuration (0:1200 – 1:2400 – 2:4800 – 3:9600 – 4:19200
30.04
– 5:38400)
30.12
Configuration of presence supervision on BMS2
30.13
BMS2 address configuration
BMS2 baud rate configuration (0:1200 – 1:2400 – 2:4800 – 3:9600 –
30.14
4:19200 – 5:38400)
ON/OFF configuration from BMS (0:Disabled – 1:Enabled)
30.05
30.09
Enable for adjustment according to the average T calculated by Climapro
(0:Disabled – 1:Enabled)
Enable the stop of direct Free Cooling from supervisor (0: Disabled – 1:
30.11
Enabled)
Alarm A contact status configuration (0:NO – 1:NC)
31.01
Alarm B contact status configuration (0:NO – 1:NC)
31.02
Addressing of the fire/smoke alarm on digital output (0:A – 1:None – 2:B)
31.03
Addressing of the phase sequence alarm on digital output (0:A – 1:None –
31.04
2:B)
Addressing of the air flow alarm on digital output (0:A – 1:None – 2:B)
31.10
31.11
Addressing of the ambient air temperature probe alarm on digital output (0:A
– 1:None – 2:B)
Addressing of the ambient humidity probe alarm on digital output (0:A –
31.12
1:None – 2:B)
Addressing of the differential pressure probe alarm on digital output (0:A –
31.13
1:None – 2:B)
31.14
Addressing of the air delivery temperature probe alarm on digital output (0:A
– 1:None – 2:B)
31.16
Addressing of the external air temperature probe alarm on digital output (0:A
– 1:None – 2:B)
Addressing of the electric heater alarm on digital output (0:A – 1:None – 2:B)
31.18
Addressing of the T+H probe offline alarm on digital output (0:A – 1:None –
31.19
2:B)
Addressing of the inverter IO expansion offline alarm on digital output (0:A –
31.23
1:None – 2:B)
Addressing of the network analyser offline alarm on digital output (0:A –
31.24
1:None – 2:B)
Addressing of the humidifier CPY module offline alarm (0:A – 1:none – 2:B)
31.25
Addressing of the LAN alarm on digital output (0:A – 1:None – 2:B)
31.50
Addressing of the low temperature alarm on digital output (0:A – 1:None –
31.51
2:B)
Addressing of the high temperature alarm on digital output (0:A – 1:None –
31.52
2:B)
Addressing of the low humidity alarm on digital output (0:A – 1:None – 2:B)
31.53
Addressing of the high humidity alarm on digital output (0:A – 1:None – 2:B)
31.54
Version 38
Description
Default
U.M.
Min.
0
-
0
11
-
1
0
-
0
4
-
0
0
-
0
2
-
1
5
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
Max.
1
207
6
5
1
207
5
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
106

Advertisement

Table of Contents
loading

Table of Contents