Par.N.
Enable APL operation in case of pressure transducer alarm (0:Disabled –
26.19
1:Enabled)
Enable the H&L Local Pressure Protection function (0:Disabled – 1:Enabled)
26.20
26.21
High local pressure function On differential
26.22
Low local pressure function On differential
26.23
Time before protection Off when the temperature is between the high and
low local pressure limits
26.24
Time before protection On when outside the limit of the high or low local
pressures
26.25
Units belonging to the LAN group (BitField encoding)
26.26
Units designated as priority masters (BitField encoding)
26.27
Units designated as forced masters (BitField encoding)
Enable the Fan Distribution Load function (0:disabled – 1:Mean LAN Return
26.28
Temp – 2:Max LAN Return Temp – 3:Min LAN Return Temp)
Active Pressure Load adjustment mode configuration (0:average – 1:min –
26.29
2:max)
Active Pressure Load modulation mode configuration (0:Control – 1:Limit)
26.30
Rotation frequency type configuration (0:disabled – 1:daily – 2:weekly –
26.31
3:monthly – 4:timed)
26.32
Weekday configuration for rotation
26.33
Hour configuration for rotation
26.34
Minute configuration for rotation
Electric heater configuration (0:Disabled – 1:Enabled)
27.02
Type of electric heating element (0:ON/OFF – 1:Modulating)
27.03
Hot gas valve configuration (0:Disabled – 1:Enabled)
27.04
Humidifier configuration (0:Disabled – 1:Internal – 2:External)
27.05
27.06
Humidifier model configuration (cylinder type)
27.07
Maximum steam production
Dehumidifier configuration (0:Disabled – 1:Enabled)
27.09
27.29
Humidification and dehumidification setpoint differential
Delivery air damper configuration (0:Disabled – 1:Enabled)
27.11
27.12
Damper opening stroke time
27.13
Line 1 network analyser presence
Line 1 power supply system type (0:3-ph unbalanced ¾-wires – 1:1-ph 2-
27.14
wires – 2:2-ph 3-wires – 3:3-ph balanced 3-wires – 4:3-ph balanced load –
5:3-ph Aron system)
27.15
Line 1 input current ampere transformation ratio
Enable the humidifier periodical drain function (0:Disabled – 1:Enabled)
27.16
27.17
Delay before each periodical drain
Enable the humidifier inactive draining function (0:Disabled – 1:Enabled)
27.18
27.19
Delay before each draining during inactivity
27.30
Line 2 network transducer presence
Line 2 power supply system type (0:3-ph unbalanced ¾-wires – 1:1-ph 2-
27.31
wires – 2:2-ph 3-wires – 3:3-ph balanced 3-wires – 4:3-ph balanced load –
5:3-ph Aron system)
Version 38
Description
Default
U.M.
Min.
0
-
0
0
-
0
10
Pa
2
10
Pa
2
300
s
10
60
s
10
-1
-
-32768
0
-
-32768
0
-
-32768
0
-
0
0
-
0
0
-
0
0
-
0
1
-
1
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
0
-
0
100
%
10
0
-
0
5
%
1
0
-
0
120
s
0
0
-
0
0
-
0
20
-
1
0
-
0
24
h
0
0
-
0
3
d
1
0
-
0
0
-
0
Max.
1
1
999
999
600
600
32767
32767
32767
3
2
1
4
7
23
59
1
1
1
2
121
100
1
10
1
500
1
5
32767
1
240
1
99
1
5
104