A&D GX-M Series Instruction Manual page 107

High-capacity precision balances
Hide thumbs Also See for GX-M Series:
Table of Contents

Advertisement

3. Press the PRINT key to store.
If the flow rate unit is g / *, the display returns to weighing display or flow display.
If the flow rate unit is mL / *, the display transitions to density setting.
Please refer to "How to set the density".
*
Unit of time setting (second(s),minute(m) or hour(h)) is entered in
How to set the density
When the setting value of function setting Frd Unit
after setting the calculation time
setting display.
Density can be changed by following key operation.
The setting range is 0.0001g/cm
RE-ZERO (+) key ꞏꞏꞏꞏꞏ Change the number of the blinking digit
MODE (-) key ꞏꞏꞏꞏꞏꞏꞏꞏꞏ Change the number of the blinking digit
SAMPLE key ꞏꞏꞏꞏꞏꞏꞏ Move the blinking digit
PRINT key ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ Store the set value and return to weighing display.
CAL key ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ Return to weighing display without storing the set
Method of reading density number
When flow unit is mL/*, up to 10 densities can be registered.
To register a new density, read the unconfigured density number
and then register according to the procedure of the setting method
of calculation time or calculation precision.
Continuing to hold down the
weighing display displays
Blinking
is the current density number and
density value.
The density number can be changed by following key operation
Note
f
** : The selected density number is entered.
d
**** : The set density number is entered.
The setting range is F01~F10.
RE-ZERO (+) key ꞏꞏꞏꞏ
MODE (-) key ꞏꞏꞏꞏꞏꞏꞏꞏꞏ
PRINT key ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ
CAL key ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ Return to the weighing display or flow display without
Change display
After returning to the weighing value display after setting to flow mode,
the unit is "g" with the
Use the
MODE
key to switch between flow rate display and "g"
display. By switching, the total amount and flow rate can be checked.
or calculation precision, go to density
3
to 9.9999g/cm
value.
PRINT
key (for 2 seconds) in
.
.
Change density number.
Change density number.
Read the density of the
number and return to weighing display.
reading the density of the selected density number.
or
indicator on.
is 3, 4, 5,
3
.
.
is the set
selected density
107
"
* " of "g/*" and "mL/*".
From the Flow calculation time
or Flow calculation precision
Press and hold
(for 2 seconds)
Weighing display
Total amount
display
Flow rate