Section 5, Detail Level Procedures
Page 84
Perform Steps Below in the Order Listed
1.
Connect a VT-100 terminal to the IQ 710.
Set the parameters of the VT-100 terminal to:
9600 baud rate
8 data bits
No parity
1 stop bit
No flow control
If the terminal has a parallel setting, disable it and use serial.
Plug one end of the DB-9 data cable into the IQ 710 Craft/Control port. Plug the other end
of the DB-9 cable into the VT-100 terminal. Make the connection to the VT-100 terminal as
appropriate for your equipment.
or:
Connect a PC emulating a VT-100 terminal to the IQ 710.
Most personal computers or laptops can run communications software that will emulate a VT-100
terminal. Windows programs such as Terminal
Windows format. However, there are many other adequate, commercially available software pack-
ages which will allow your PC or laptop to emulate a VT-100 terminal. Certain configuration
items must be set on a PC or laptop to act as a VT-100 terminal for the IQ 710.
Set the PC for direct connect on the appropriate com port (instead of dial up connection).
Set the parameters of the communications software to:
9600 baud rate
8 data bits
No parity
1 stop bit
No flow control
Plug one end of the DB-9 data cable into the IQ 710 Craft/Control port. Plug the other end
of the DB-9 cable into the com port of the PC or laptop. Make connection to the PC or lap-
top as appropriate for your equipment.
You are now ready to login to the IQ 710, as described in DLP-002, Logging in to the System.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.