5. PARAMETERS
5.3 Extension setting parameters (No. PC

5.3.1 Parameter list

No.
Symbol
Error excessive alarm level
PC01
ERZ
Electromagnetic brake sequence output
PC02
MBR
PC03 *ENRS Encoder output pulses selection
PC04 **COP1 Function selection C-1
PC05 **COP2 Function selection C-2
PC06 *COP3 Function selection C-3
Zero speed
PC07
ZSP
For manufacturer setting
PC08
PC09 MOD1 Analog monitor 1 output
PC10 MOD2 Analog monitor 2 output
Analog monitor 1 offset
PC11
MO1
Analog monitor 2 offset
PC12
MO2
PC13 MOSDL Analog monitor feedback position output standard data Low
PC14 MOSDH Analog monitor feedback position output standard data High
For manufacturer setting
PC15
PC16
PC17 **COP4 Function selection C-4
For manufacturer setting
PC18
PC19
PC20
Alarm history clear
PC21
*BPS
PC22
For manufacturer setting
PC23
PC24
PC25
PC26
PC27
PC28
PC29
PC30
PC31
PC32
)
POINT
Parameter whose symbol is preceded by * is made valid with the following
conditions.
* : Set the parameter value, switch power off once after setting, and then
switch it on again, or perform the controller reset.
**: Set the parameter value, switch power off once, and then switch it on
again.
Name
5 - 17
Initial Value
Unit
3
rev
0
ms
0000h
0000h
0000h
0000h
50
r/min
0
0000h
0001h
0
mV
0
mV
0
pulse
0
10000
pulse
0
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h