6-3. Analog Video Playback System Adjustment after Replacing the Drum
OXIDE C adjustment [up to step (16)]
(14) Observe the R-Y output signal on the component waveform monitor.
(15) Playback the multiburst signal portion (3:00 to 6:00) of the alignment tape CR5-2A or CR5-2A PS,
and adjust so that the level at 1 MHz portion is within specification. And confirm that levels at other
frequencies are within specifications.
(DNW-A100/A50/A45: CR5-2A, DNW-A100P/A50P/A45P: CR5-2A PS)
n
The overlapping waveform of A channel and B channel signals is monitored on the component
waveform monitor. So adjust/confirm the signal level at each channel.
Adjustment points: A channel:
B channel:
Specifications (A and B channels): Show the table below.
Frequency
Specification for DNW-A100/A50/A45
7T BAR
Reference: 100% {0 dB}
1 MHz
Adjust : 94 (100 to 89)%
0.2 MHz
Check : 100 (106 to 71)%
0.5 MHz
Check : 95 (106 to 71)%
1.5 MHz
Check : 80 (106 to 71)%
7T BAR
0.2
100%
DNW-A100/A50/A45
(16) Observe the B-Y output signal on the component waveform monitor. Confirm the B-Y signal levels
at each frequencies are within specifications shown above. If the B-Y signal is out of specifications,
perform fine adjustment for R-Y until the specifications for both B-Y and R-Y signals are satisfied.
(17) Eject the alignment tape CR5-2A/CR5-2A PS.
(18) To exit from A32 : DM VR 1, press the MENU button once.
Saving data [up to step (21)]
(19) Select A3F : NV-RAM CONTROL of the maintenance mode, and execute "SAVE ALL ADJUST
DATA".
(20) Check that the message "Save Complete" is displayed on the video monitor.
(21) To exit from A3F : NV-RAM CONTROL, press the MENU button once.
6-30
A32 : DM VR 1 : EQ1 OXIDE-C-A
A32 : DM VR 1 : EQ1 OXIDE-C-B
{_0.5 ± 0.5 dB}
+0.5
{0
dB}
_3.0
+0.9
{_0.4
dB}
_2.6
+2.5
{_2.0
dB}
_1.0
0.5
1
1.5
2
[MHz]
Frequency
Specifications for DNW-A100P/A50P/A45P
8T BAR
Reference: 100% {0 dB}
1 MHz
Adjust : 94 (102 to 86)%
0.2 MHz
Check : 100 (106 to 71)%
0.5 MHz
Check : 100 (106 to 71)%
1.5 MHz
Check : 84 (106 to 71)%
8T BAR
0.2 0.5 1 1.5 2
100%
DNW-A100P/A50P/A45P
{_0.5 ± 0.8 dB}
+0.5
{0
dB}
_3.0
+0.5
{0
dB}
_3.0
+2.0
{_1.5
dB}
_1.5
[MHz]
DNW-A100/A50/A45
DNW-A100P/A50P/A45P