5. Attach the Drum Assembly
(1) Confirm that there is no clearance between
the spacer and the washer of the demagneti-
zation head assembly. (If clearance exists,
tighten the hexagonal screw.)
Then insert the demagnetization head into the
hole of the drum support, and tighten the
hexagonal screw.
Tightening torque: 39.2
{4 kgf . cm}
(2) Hold the drum support and connect the three
connectors disconnected in (6) of step 3.
m
. Hold the height determining plate and the
drum support at that time. Be careful not to
hold the upper drum and the brush slip ring
assembly.
. Pay attention to the direction of the connec-
tors.
(3) Fix each of the two harnesses with the
harness holder as shown in the figure.
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
. . . . . Install the demagnetization head assembly
Hexagonal screw
10
_2
N . m
x
22-pin
Spacer
Washer
No clearance.
Hexagonal screw
Drum support
Demagnetization head assembly
Tightening torque : 39.2 x 10
• When connecting the Harnesses
14-pin
16-pin
Harness holders
Attach the Drum Assembly
5-3. Drum Assembly Replacement
_2
N.m {4kgf . cm}
• How to fix the harness
5-23