3-9. TBC Remote Control Offset Adjustment (FP-91 Board)
Adjustment without the Shorting Connector
n
Be sure to short-circuit VIDEO CONTROL connector's
pins in the power off.
Never short-circuit this connector's pin 7 (+12 V) or pin
15 (_12 V) to other pin.
1. Turn off the POWER switch.
2. Short-circuit VIDEO CONTROL connector's pin 8
(GND) to one of the satisfied pin on the table below.
3. Turn on the POWER switch.
4. Connect the digital voltmeter to the specified measure-
ment point on the table below.
5. Adjust the voltage on the digital voltmeter.
Adj. points:
Refer to table below.
Specification: 2.500 ± 0.001 V dc
6. Repeat from step 1 until completing the adjustments
for all adjustment points.
Pin No. to short-circuit
[Adjusting item]
1 [ SYNC PHASE ]
2 [ CHROMA PHASE ]
3 [ SC PHASE ]
4 [ VIDEO LEVEL ]
5 [ SETUP(BLACK) LEVEL ] TP3/FP-91(C-2) 1RV3/FP-91(C-2)
6 [ CHRAMA LEVEL ]
13 [ Y/C DELAY ]
A
B
1
2
RV1
RV2
RV3
TP1
TP2
TP3
3
MADE IN JAPAN
4
CN224
5
A No.
LOTNO,
S NO,
FP-91 Board (Side A)
3-110
Measurement
Adjustment
point
point
TP6/FP-91(D-2) 1RV6/FP-91(D-2)
TP5/FP-91(D-2) 1RV5/FP-91(D-2)
TP7/FP-91(D-2) 1RV7/FP-91(D-2)
TP1/FP-91(B-2) 1RV1/FP-91(B-2)
TP2/FP-91(B-2) 1RV2/FP-91(B-2)
TP4/FP-91(C-2) 1RV4/FP-91(D-2)
CN147
C
D
E
RV4
RV5
RV6
RV7
TP4
TP5
TP6
TP7
E1
>EP–GW<
A
FP-91
1-661-138-
CN31
Adjustment with the Shorting Connector
n
Be sure to connect the shorting connector in the power off.
1. Turn off the POWER switch.
2. Connect the shorting connector to VIDEO CONTROL
connector.
3. Turn on the POWER switch.
4. Adjust each voltage on the digital voltmeter.
Measure. point: Refer to the table below.
Adj. point:
Refer to the table below.
2.500 ± 0.001 V dc
Specification:
Adjusting item
Measurement
point
VIDEO LEVEL
TP1/FP-91(B-2)
CHRAMA LEVEL
TP2/FP-91(B-2)
SETUP(BLACK) LEVEL TP3/FP-91(C-2)
Y/C DELAY
TP4/FP-91(C-2)
CHROMA PHASE
TP5/FP-91(D-2)
SYNC PHASE
TP6/FP-91(D-2)
SC PHASE
TP7/FP-91(D-2)
Perfection
1. Turn off the POWER switch.
2. Reinstall the audio level meter module.
(Perform in the reverse steps 2 and 3 of "Preparation".)
m
. This module's displaying side is glass. Be sure to
handle with care.
. Fix the earth wire and this module (its left part)
together .
3. Reattach the panel for the upper control panel.
4. When the shorting connector was used, remove it.
Adjustment
point
1RV1/FP-91(B-2)
1RV2/FP-91(B-2)
1RV3/FP-91(C-2)
1RV4/FP-91(D-2)
1RV5/FP-91(D-2)
1RV6/FP-91(D-2)
1RV7/FP-91(D-2)
DNW-A100/A50/A45
DNW-A100P/A50P/A45P

Advertisement