5-20. Threading Ring and Ring Roller Replacement
23. T Drawer Assembly Installation
(1) Clean the mounting surface of the T drawer
assembly and chassis.
(2) Set the T drawer assembly and tighten with
the two screws.
(3) Connect the harness to the connector of the
tape top sensor.
(4) Fix the harness to the holder of the
adjustment plate.
5-144
T drawer assembly
Connector
Screws
(PWH3 x 8)
Cleaning
Cleaning
T Drawer Assembly Installation
. Fixing the harness
Harness
Cleaning
SE-341 board
Harness
Harness
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
Holder