9. Cleaning
Clean the lower surface (shaded portion in the
figure) of the height determining plate and the
upper surface of the drum support (shaded portion
in the figure) with a soft cloth.
10. Attach the Height Determining Plate
(1) Attach the height determining plate so that
the positioning pins of the drum support are
put into the holes of the height determining
plate.
(2) Alternately and gradually tighten the two
screws.
Tightening torque: 78.4
{8 kgf . cm}
11. Put the Demagnetization Head
Assembly Back
Turn the knob of the demagnetization head
assembly clockwise until it will be stopped.
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
. . . . . Drum support
_2
N . m
10
X
Positioning pins
Lower surface of
height determining
plate (Cleaning)
Drum support
(Cleaning)
Cleaning
Screw(C3 x 8)
Screw(C3 x 8)
Height determining
plate
Drum support
Knob
Tightening torque : 78.4 x 10
Attach the Height Determining Plate/
Put the Demagnetization Head Aassembly Back
5-2. Upper Drum Assembly Replacement
_2
N . m {8 kgf . cm}