5. Analog Composite Input Level (AGC) Adjustment
(1) Connect as connection 1.
(2) Select C22: MULTI LOOP (10 TIMES) of C2: AUDIO/VIDEO CHECK of the maintenance mode.
(3) Set the test signal to "100% Color Bars".
(4) Push MENU button once so as to exit C22: MULTI LOOP (10 TIMES).
(5) Select A25: DEC VR of A2: AUDIO/VIDEO ADJUST.
(6) Select "AGC VIDEO GAIN".
(7) Adjust "AGC VIDEO GAIN" that the specification is satisfied.
VIDEO OUTPUT COMPOSITE 2
Before adjustment
Specification: The white level of the signal after looping overlaps on the 1st signal.
[|Supplement|] The signal after looping is displaied in a state of overlapping on 1st signal on the screen of the waveform monitor.
They appear that the 1st signal is freezing and the signal after looping is changing the fluctuation level.
(8) After completing the adjustment, push the MENU button once so as to exit A25: DEC VR.
(9) Select A2F: NV-RAM CONTROL and save the adjusted data in NV-RAM (execute "SAVE ALL
ADJUST DATA").
(10)Check that the message "Save Complete" is displayed on the video monitor screen.
(11)Push the MENU button once so as to exit A2F: NV-RAM CONTROL.