5-8. CTL Head Replacement
Installation
4. Mount the CTL Head
(1) Solder the connector pin to the CTL head
board.
(2) Temporarily tighten the two screws while
moving the CTL head in the direction
indicated by arrows A and B.
n
Be careful not to damage the CTL and full
erase head.
(3) Confirm that the specification is met, secure-
ly tighten the two screws.
Tightening torque: 19.6 x 10
{2.0 kgf . cm}
5-42
_2
N . m
CTL/FE bracket
Connector pin
CTL head
A
B
CTL head
Spec. : The side of the CTL head and the edge
of the CTL/FE bracket are the same
surface.
Same surface
Mount the CTL Head
Full-erase head
Spring washers
CTL head securing screws
(P2 x 3)
DNW-A100/A50/A45
DNW-A100P/A50P/A45P