7. Attach the Demagnetization Head
Assembly
(1) Confirm that there is no clearance between
the spacer and the washer of the demagneti-
zation head assembly. (If clearance exists,
tighten the hexagonal screw.)
Then insert the demagnetization head into the
hole of the drum support, and tighten the
hexagonal screw.
Tightening torque: 39.2 x 10
{4 kgf . cm}
n
Put portion "a" of the demagnetization head
assembly under the knob.
(2) Turn the knob of the demagnetization head
clockwise with fingers and tighten the knob
as far as it will go.
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
• Install the demagnetization head assembly
_2
N . m
Hexagonal screw
Demagnetization
head assembly
Hexagonal screw
Washer
No clearance
a
Knob
Attach the Demagnetization Head Assembly
5-10. Capstan Motor Replacement
Spacer
5-69