 To restore, set bit 13 in SR214 to 0.
 To backup devices, set bit15 in SR214 to 1.
M1
For example, if the value in SR214 is 8000H, the file \AHMotion\Device\0.csv in a memory card will
be restored to the motion control module.

13.5 Program Backup and Restoration

13.5.1 Backup

The operation for a program backup is described below,
1. Monitor an AH500 series motion control module by PMSoft, and stop the operation under the
monitoring. Alternatively, set SM072 to 0 to stop O100.
2. Set SR214 by a device monitoring table or external communication.
 Set bit 12~bit 0 in SR214 to bit 0. The values of bit 12~bit 0 in SR214 represent a backup
file name.
 To backup, set bit 13 in SR214 to 1.
 To backup the program in the AH500 series motion control module, set bit 14 in SR214 to 1.
After the program backup is completed, a .raw file which includes the password for the backup
program will be generated in \AHMotion\Program\ in a memory card. The table above shows that
the name of the .raw file is 0.raw.
Ch ap te r 13 Expa nsio n Storage De vice
MOV
H8000
SR214
1 3 - 7