Delta Electronics AH500 Manual page 234

Motion control module
Hide thumbs Also See for AH500:
Table of Contents

Advertisement

 Suppose the value in S
E xamp le 2
 Eequation: D10=[(500–200)×(30–500)]÷(3,000–200)+500=449.64
 Suppose S
 Equation: D10=[(F500–F200)×(F500–F30)]÷(F3000–F200)+F30=F80.35
5 - 11 9
3,000, the minimum source value in D1 is 200, the maximum destination
value in D2 is 30, and the minimum destination value in D3 is 500. When
X0.0 is ON, the instruction SCLP is executed, and a scale is stored in
D10.
449.64 is rounded to the nearest integer, and becomes 450. 450 is
stored in D10.
X0.0
X0.0
Destinati on value
Minimum des tination
value=500
D
Maximum destination
value=30
0
Minimum
sourc e value=200
is D100, the value in D100 is F500, the maximum source
1
value in D0 is F3000, the minimum source value in D2 is F200, the
maximum destination value in D4 is F500, and the minimum destination
value in D6 is F30. When X0.0 is ON, M1162 is set to ON, the instruction
DSCLP is executed, and a scale is stored in D10.
F80.35 is rounded to the nearest integer, and becomes F80. F80 is
stored in D10.
X0.0
X0.0
Ch ap te r 5 Ap plie d Instruc tions
is 500, the maximum source value in D0 is
1
MO V
K3000
K200
MO V
K30
MO V
K 500
MO V
SCLP
K500
S
500
1 =
Maximum
sourc e value=3000
SET
M1162
F500
D 100
D MO VR
D MO VR
F3000
F200
D MO VR
F500
D MO VR
F30
D MO VR
D SC LP
D 100
D0
D 0
D 1
D 2
D 3
D 0
D10
Sourc e value
D 0
D 2
D 4
D 6
D10