Bit
Field
RX_AGC_SMALL_
7-0
STEP_ATTACK_W
IN_LEN[15:8]
2.13.84 Register 41Ah (offset = 41Ah) [reset = 40h]
7
6
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Bit
Field
RX_AGC_SMALL_
7-0
STEP_ATTACK_W
IN_LEN[23:16]
2.13.85 Register 41Ch (offset = 41Ch) [reset = 0h]
7
6
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Bit
Field
RX_AGC_BIG_ST
7-0
EP_DECAY_WIN_
LEN[7:0]
2.13.86 Register 41Dh (offset = 41Dh) [reset = 80h]
7
6
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Bit
Field
RX_AGC_BIG_ST
7-0
EP_DECAY_WIN_
LEN[15:8]
SBAU337 – May 2020
Submit Documentation Feedback
Table 2-1508. Register 419 Field Descriptions
Type
Reset
R/W
0h
Figure 2-1496. Register 41Ah
5
4
RX_AGC_SMALL_STEP_ATTACK_WIN_LEN[23:16]
R/W-40h
Table 2-1509. Register 41A Field Descriptions
Type
Reset
R/W
40h
Figure 2-1497. Register 41Ch
5
4
RX_AGC_BIG_STEP_DECAY_WIN_LEN[7:0]
R/W-0h
Table 2-1510. Register 41C Field Descriptions
Type
Reset
R/W
0h
Figure 2-1498. Register 41Dh
5
4
RX_AGC_BIG_STEP_DECAY_WIN_LEN[15:8]
R/W-80h
Table 2-1511. Register 41D Field Descriptions
Type
Reset
R/W
80h
Copyright © 2020, Texas Instruments Incorporated
Description
Digital small step attack det window length. Max supported
length is 2^24 - 2.
3
2
Description
Digital small step attack det window length. Max supported
length is 2^24 - 2.
3
2
Description
Digital big step decay det window length. Max supported
length is 2^24 - 2.
3
2
Description
Digital big step decay det window length. Max supported
length is 2^24 - 2.