IO Wrap Register Map
Bit
Field
READ_INTPO_AL
0-0
ARM_2
2.16.652 Register 1419h (offset = 1419h) [reset = 0h]
7
6
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Bit
Field
READ_INTPO_DA
0-0
C_SYNC_N_AB_0
2.16.653 Register 141Ah (offset = 141Ah) [reset = 0h]
7
6
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Bit
Field
READ_INTPO_DA
0-0
C_SYNC_N_AB_1
2.16.654 Register 141Fh (offset = 141Fh) [reset = 0h]
7
6
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Bit
Field
READ_INTPO_API
0-0
_DONE_INTERRU
PT
1214
Serial Interface Register Maps
Table 2-2930. Register 1418 Field Descriptions
Type
Reset
R
0h
Figure 2-2915. Register 1419h
5
4
Table 2-2931. Register 1419 Field Descriptions
Type
Reset
R
0h
Figure 2-2916. Register 141Ah
5
4
Table 2-2932. Register 141A Field Descriptions
Type
Reset
R
0h
Figure 2-2917. Register 141Fh
5
4
Table 2-2933. Register 141F Field Descriptions
Type
Reset
R
0h
Copyright © 2020, Texas Instruments Incorporated
Description
read only register for function intpo_alarm_2
3
2
Description
read only register for function intpo_dac_sync_n_ab_0
3
2
Description
read only register for function intpo_dac_sync_n_ab_1
3
2
Description
read only register for function intpo_api_done_interrupt
Submit Documentation Feedback
www.ti.com
1
0
READ_INTPO_
DAC_SYNC_N
_AB_0
R-0h
1
0
READ_INTPO_
DAC_SYNC_N
_AB_1
R-0h
1
0
READ_INTPO_
API_DONE_IN
TERRUPT
R-0h