<Work procedure 2-3>
Replacement Procedure
1) Open the Front Left Cover and the Front Right Cover.
2) Remove Process Unit Cover.
3) Pull Out ITB Unit.
CAUTION:
Be sure to pull out the Fixing Feed Unit and ITB Unit to the position where latch is locked.
Reason: Disengagement between the Positioning Pin of the Secondary Transfer Outer Unit and Shaft
Support Member of the frame body of the ITB Unit becomes insufficient, and it may cause damage when
assembling the Intermediate Transfer Belt Unit.
4) Remove ITB Cleaning Unit.
5) Remove Patch Sensor Unit.
6) Remove the connector.
7) Hold the grip and with opening the intermediate transfer belt unit, remove the support shaft.
6 / 8