< Work procedure 1-4>
Check the Shaft Support Members of the Process Unit for any damage. [D-2]
1) Open the Front Left Cover and the Front Right Cover.
2) Remove Process Unit Cover.
3) Pull Out Process Unit.
4) Check the 2 Shaft Support Members [1] of the Process Unit and the 2 pins [2] of the Positioning Plate of
the Process Unit for any abnormality.
5) If abnormality is found, replace the faulty part.
6) Install the removed parts in reverse order.
Check the Shaft Support Members of the Fixing Assembly for any damage. [D-3]
1) Open the Front Left Cover and the Front Right Cover.
2) Pull Out Fixing Feed Unit.
3) Remove the fixing feed cover (upper).
- 2 screws
10 / 12