<Work procedure 2-8>
29) Install the Fixing Pressure Unit to the Fixing Assembly.
Caution : caution when installing the fixing pressure unit
Check from the hole of the fixing assembly and make sure that the cam is the same status as when the fixing
pressure unit is removed. If not, turn the gear to take the cam back to the position as when the fixing pressure
unit is removed because the fixing pressure unit cannot be installed correctly.
- When making the cam from the lying status [B] to the standing status [A].
- When making the cam from the standing status [A] to the lying status [B].
Caution :
Be sure that the screw of the cam is in the correct direction when making the cam in a lying state. If the
direction is incorrect, the cam may not rotate normally.
30) Install the removed parts in reverse order.
9 / 9

Advertisement