Toro Groundsmaster 4500-D Series Service Manual page 59

Hide thumbs Also See for Groundsmaster 4500-D Series:
Table of Contents

Advertisement

Fault
Fault Title
ID
C14E4
PTO 3 - Short
to Ground /
Overcurrent
C14E5
PTO 3 - Open
Circuit
C14F4
PTO 4 - Short
to Ground /
Overcurrent
C14F5
PTO 4 - Open
Circuit
C1514
Hydraulic
Pressure Sensor
1 - Short to
Ground
C1515
Hydraulic
Pressure Sensor
1 - Open Circuit
P0225
Traction Pedal 1
Analog Sensor 1
- Open Circuit
Groundsmaster
®
4500-D/4700-D
19245SL Rev A
Contro-
Fault Condition
ller(s)
/ Circuit
Affected
Description
T2
Overcurrent
detected on PTO
left SV2 output
indicating a short
to ground.
T2
Open circuit
detected on PTO
left SV2 output.
T2
Overcurrent
detected on deck
PTO right SV1
output indicating a
short to ground.
T2
Open circuit
detected on deck
PTO right SV1
output.
T1
Front hydraulic
pressure sensor
(traction pressure)
is shorted to
ground (out of
range low).
T1
Front hydraulic
pressure sensor
(traction pressure)
is open (out of
range high).
T1
Traction pedal
analog sensor 1
(neutral forward
and neutral
reverse) is reading
a voltage outside
the range it
was designed to
operate, indicating
an open circuit.
Additional
Notes
1.
Test the output circuit for a short.
2.
Test for proper resistance in the component
connected to the auxiliary TEC (P75, pin
42).
3.
Swap the T2: Auxiliary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for an open.
2.
Test for proper resistance in the component
connected to the auxiliary TEC (P75, pin
42).
3.
Swap the T2: Auxiliary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for a short.
2.
Test for proper resistance in the component
connected to the auxiliary TEC (P75, pin
41).
3.
Swap the T2: Auxiliary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for an open.
2.
Test for proper resistance in the component
connected to the auxiliary TEC (P75, pin
41).
3.
Swap the T2: Auxiliary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Check for the pressure sensor wiring and
connector (P74, pin 11).
2.
Test the pressure sensor wiring.
3.
Test the pressure sensor.
4.
Replace the pressure sensor.
1.
Check for the pressure sensor wiring and
connector (P74, pin 11).
2.
Test the pressure sensor wiring.
3.
Test the pressure sensor.
4.
Replace the pressure sensor.
Traction is
1.
Use the InfoCenter to verify sensor
disabled.
movement.
2.
If no voltage is displayed:
A.
B.
3.
Check the sensor wiring to the TEC
controller. (P74, pins 17 and 32).
4.
Test the traction pedal assembly.
5.
Replace the sensor.
Page 3–19
Service Actions
Check the traction pedal wiring and
connector (P01, pins D and E).
Test the sensor wiring.
Troubleshooting: