Lift Control Manifold Service (GM4700-D) (continued)
Groundsmaster
®
4500-D/4700-D
19245SL Rev A
If lift manifold is attached to machine, make sure that cutting decks
are fully lowered before loosening hydraulic lines, cartridge valves
or plugs from lift manifold. If decks are raised as components are
loosened, decks may drop unexpectedly.
g308994
1.
Manifold body
2.
Straight fitting (3 used)
3.
Zero leak plug (#4)
4.
Orifice (0.063)
For solenoid and control valve service procedures, see
Service (GM4500-D) (page
cartridge valve and plug installation torque.
WARNING
Figure 147
5.
Orifice (0.080)
6.
O-ring
7.
O-ring
5–134). Refer to
Figure 146
Page 5–161
Deck Control Manifold
and
Figure 147
Hydraulic System: Service and Repairs
for