Fault
Fault Title
ID
C1463
Solenoid 6 -
Short to Battery
C1464
Solenoid 6 -
Short to Ground
/ Overcurrent
C1465
Solenoid 6 -
Open Circuit
C1473
Solenoid 7 -
Short to Battery
C1474
Solenoid 7 -
Short to Ground
/ Overcurrent
C1475
Solenoid 7 -
Open Circuit
Troubleshooting:
Contro-
Fault Condition
ller(s)
/ Circuit
Affected
Description
T1
Low current
detected on center
deck float S6
output indicating
a short to a high
(+) source. This
short could be to
battery voltage or
to another signal
that is in a high
state.
T1
Overcurrent
detected on center
deck float S6
output indicating
a short to ground.
T1
Open circuit
detected on center
deck float S6
output.
T2
Low current
detected on right
deck raise S7
output indicating
a short to a high
(+) source. This
short could be to
battery voltage or
to another signal
that is in a high
state.
T2
Overcurrent
detected on right
deck raise S7
output indicating
a short to ground.
T2
Open circuit
detected on right
deck raise S7
output.
Additional
Notes
1.
Test the output circuit for a short.
2.
Test for proper resistance in the component
connected to the primary TEC (P74, pin 3).
3.
Swap the T1: Primary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for a short.
2.
Test for proper resistance in the component
connected to the primary TEC (P74, pin 3).
3.
Swap the T1: Primary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for an open.
2.
Test for proper resistance in the component
connected to the primary TEC (P74, pin 3).
3.
Swap the T1: Primary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for a short.
2.
Test for proper resistance in the component
connected to the auxiliary TEC (P75, pin
6).
3.
Swap the T2: Primary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for a short.
2.
Test for proper resistance in the component
connected to the auxiliary TEC (P75, pin
6).
3.
Swap the T2: Auxiliary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Test the output circuit for an open.
2.
Test for proper resistance in the component
connected to the auxiliary TEC (P75, pin
6).
3.
Swap the T2: Auxiliary controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
Page 3–16