Traction Pedal Position Sensor Calibration (continued)
Electrical System: Adjustments
g309424
g309425
4. Use the InfoCenter Display Service menu (see
6–8)) to obtain and select the Traction Pedal menu item. The InfoCenter
display should indicate that the traction pedal calibration process is engaged
(Figure
183).
5. Follow the prompts on the InfoCenter display screen to calibrate the traction
pedal position sensor. The calibration steps are listed below:
A. Slowly press traction pedal to the forward direction.
B. Press and hold traction pedal to the full forward position.
C. Allow traction pedal to return to the neutral position.
D. Slowly press traction pedal to the reverse direction.
E. Press and hold traction pedal to the full reverse position.
F. Check that InfoCenter display indicates a successful calibration process
(Figure
184).
6. Turn ignition switch to OFF which exits the traction pedal calibration menu.