Procedure for Traction Circuit Relief Pressure Test (continued)
Hydraulic System: Testing
9. When testing is completed, disconnect pressure gauge from diagnostic test
fitting. If reverse traction circuit was tested, remove test fitting, 90º fitting and
straight fitting from piston (traction) pump. Install plug into piston pump port
and torque plug to 43 N·m (32 ft-lb).