Removal
(Figure
142) (continued)
Installation
(Figure
Groundsmaster
®
4500-D/4700-D
19245SL Rev A
g308987
1.
Lift manifold (GM4700-D)
2.
Dust cap
3.
Test fitting (2 used)
4.
O-ring
5.
O-ring
7. Remove hydraulic manifold from the frame using
8. If hydraulic fittings are to be removed from lift control manifold, mark fitting
orientation to allow correct assembly
fittings from manifold and discard O-rings.
142)
1. If fittings were removed from lift control manifold, lubricate and place new
O–rings onto fittings. Install fittings into manifold openings using marks made
during the removal process to properly orientate fittings. Tighten fittings (see
Installing the Hydraulic Fittings (SAE Straight Thread O-Ring Fittings) (page
5–9)). Refer to
Figure 143
2. Install hydraulic manifold to the frame using
3. Remove caps and plugs from fittings and hoses. Properly connect hydraulic
lines to manifold (see
Seal) (page
5–7)).
4. Connect wire harness electrical connectors to the solenoid valve coils.
5. Lower and secure operator seat.
Figure 144
GROUNDSMASTER 4700-D
6.
Straight fitting (2 used)
7.
O-ring
8.
O-ring
9.
Straight fitting (2 used)
10.
O-ring
(Figure 143
or
Figure 144
for fitting installation torque.
Installing Hydraulic Hoses and Tubes (O-Ring Face
Page 5–157
Figure 142
as guide.
or
Figure
144). Remove
Figure 142
as guide.