278
Figure 81: Removing the Air Filter
SEE ALSO
Preventing Electrostatic Discharge Damage to an MX240 Router | 467

Installing the MX240 Air Filter

To install the air filter (see
Figure 82 on page
279):
1. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
2. Locate the up arrow and ensure that the air filter is right side up.
3. Slide the air filter straight into the chassis until it stops.
4. Align the captive screws of the air filter cover with the mounting holes on the chassis.
5. Tighten the captive screws on the air filter cover.