Replacing an MX240 FPC

Removing an MX240 FPC | 331

1.
Installing an MX240 FPC | 333
2.
Removing an MX240 FPC
When you remove an FPC, the router continues to function, although the PIC interfaces installed on the
FPC being removed no longer function.
An FPC takes up two DPC slots on the MX240 router. One FPC can be installed horizontally in the front
of the router. The FPCs are hot-insertable and hot-removable. A fully configured FPC can weigh up to
18 lb (8.2 kg). Be prepared to accept its full weight.
To remove an FPC (see
Figure 114 on page
1. Have ready a replacement FPC or FPC blank panel and an antistatic mat for the FPC. Also have ready
rubber safety caps for each PIC using an optical interface on the FPC that you are removing.
2. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
3. Label the cables connected to each PIC on the FPC so that you can later reconnect the cables to the
correct PICs.
4. Use one of the following methods to take the FPC offline:
Press and hold the FPC online/offline button. The green OK LED next to the button begins to blink.
Hold the button down until the LED goes off. The LEDs and online/offline button for each FPC are
located directly above it on the craft interface.
Issue the following CLI command:
user@host>request chassis fpc slot slot-number offline
For more information about the command, see the
NOTE:
is installed.
5. Disconnect the cables from the PICs installed in the FPC.
333):
The slot number corresponds to the lowest numbered slot for which the FPC
CLI