PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 1
Online
For further description of the output from the command, see the
SEE ALSO
MX240 Modular Port Concentrator (MPC) Description | 154
MX240 Modular Port Concentrator (MPC) LEDs | 156
Troubleshooting the MX240 MPCs | 434

Replacing an MX240 MPC

Removing an MX240 MPC | 347

1.
Installing an MX240 MPC | 350
2.
Removing an MX240 MPC
When you remove an MPC, the router continues to function, although the MIC interfaces installed on the
MPC being removed no longer function.
An MPC installs horizontally in the front of the router. The MPCs are hot-insertable and hot-removable.
A fully configured MPC can weigh up to 18.35 lb (8.3 kg). Be prepared to accept its full weight.
To remove an MPC (see
1. Have ready a replacement MPC or DPC blank panel and an antistatic mat for the MPC. Also have ready
rubber safety caps for each MIC using an optical interface on the MPC that you are removing.
2. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
3. Label the cables connected to each MIC on the MPC so that you can later reconnect the cables to the
correct MICs.
4. Use one of the following methods to take the MPC offline:
4x 10GE(LAN) SFP+
MS-DPC
MS-DPC PIC
MS-DPC PIC
Figure 122 on page
349):
CLI
Explorer.