Maintaining MX240 Components
IN THIS SECTION
Routine Maintenance Procedures for the MX240 Router | 271
Tools and Parts Required to Maintain the MX240 Router | 272
MX240 Field-Replaceable Units (FRUs) | 272
Tools and Parts Required to Replace MX240 Hardware Components | 273
Routine Maintenance Procedures for the MX240 Router
Purpose
For optimum router performance, perform preventive maintenance procedures.
Action
Inspect the installation site for moisture, loose wires or cables, and excessive dust. Make sure that airflow
is unobstructed around the router and into the air intake vents.
Check the status-reporting devices on the craft interface—System alarms and LEDs.
Inspect the air filter at the left rear of the router, replacing it every 6 months for optimum cooling system
performance. Do not run the router for more than a few minutes without the air filter in place.
SEE ALSO
Maintaining the MX240 Air Filter | 276
Maintaining the MX240 Fan Tray | 279
Maintaining the MX240 Host Subsystem | 285