Juniper MX240 Hardware Manual page 311

Universal routing platform.
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

On a regular basis:
Check the LEDs on the craft interface directly above each DPC slot. The green LED labeled OK lights
steadily when a DPC is functioning normally.
Check the OK/FAIL LED on the DPC. If the DPC detects a failure, the DPC sends an alarm message to
the Routing Engine.
Issue the CLI show chassis fpc command to check the status of installed DPCs. As shown in the sample
output, the value State in the column labeled State indicates that the DPC is functioning normally:
user@host> show chassis fpc
Slot State
0
Online
1
Online
2
Online
For more detailed output, add the detail option. The following example does not specify a slot number,
which is optional:
user@host> show chassis fpc detail
Slot 0 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Slot 1 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Slot 2 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Temp
CPU Utilization (%)
(C)
Total
Interrupt
41
9
43
5
43
11
33 degrees C / 91 degrees F
1024 MB
256 MB
4096 MB
33 degrees C / 91 degrees F
1024 MB
256 MB
4096 MB
33 degrees C / 91 degrees F
1024 MB
256 MB
4096 MB
Memory
Utilization (%)
DRAM (MB) Heap
0
1024
15
0
1024
16
0
1024
16
Online
2007-12-06 11:33:00 PST
4 hours, 34 minutes, 49 seconds
Online
2007-12-06 11:33:01 PST
4 hours, 34 minutes, 48 seconds
Online
Buffer
57
57
57
315

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents