Storing an MX240 FPC

When not installed in the routers, FPCs must be either stored in the container in which a spare FPC is
shipped or stored horizontally with the component-side up on a flat, stable surface. When you store an
FPC on a horizontal surface or in the shipping container, always place it inside an antistatic bag. Because
the FPC is heavy and because antistatic bags are fragile, inserting the FPC into the bag is easier with two
people. The storage guidelines are as follows:
When two people are storing an FPC, one person holds the FPC in the horizontal position with the
faceplate facing their body, the other person slides the opening of the bag over the FPC connector edge.
When one person is storing an FPC, you must insert the FPC into a bag by yourself. First lay the FPC
horizontally on a flat, stable surface, component-side up. Orient the FPC with the faceplate facing you.
Carefully insert the FPC connector edge into the opening of the bag, and pull the bag toward you to
cover the FPC.
CAUTION:
Never lay an FPC component-side down.
Never stack an FPC under or on top of any other component (see
Figure 113 on page
Figure 113: Do Not Stack FPCs
SEE ALSO
MX240 FPC Terminology
Holding an MX240 FPC | 326
To prevent damage when storing FPCs:
330).
330