Mx240 Router Environmental Specifications - Juniper MX240 Hardware Manual

Universal routing platform.
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

Table 78: Physical Specifications (continued)
Description
High-capacity AC power
supply
SEE ALSO
MX240 System Overview | 29
MX240 Chassis Description | 32
MX240 Chassis Lifting Guidelines | 469

MX240 Router Environmental Specifications

Table 79 on page 180
specifies the environmental specifications required for normal router operation. In
addition, the site should be as dust-free as possible.
Table 79: Routers Environmental Specifications
Description
Altitude
Relative humidity
Temperature
Seismic
Maximum thermal output
Weight
Width
6.6 lb (2.99 kg)
14.5 in. (36.8 cm)
Value
No performance degradation to 10,000 ft (3048 m)
Normal operation ensured in relative humidity range of 5% to
90%, noncondensing
Normal operation ensured in temperature range of 32°F (0°C)
to 104°F (40°C)
Nonoperating storage temperature in shipping container:
–40°F (–40°C) to 158°F (70°C)
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
AC power: 7161 BTU/hour (2100 W)
DC power: 5074 BTU/hour (1488 W)
Depth
Height
4 in. (10.2 cm)
1.75 in. (4.4 cm)
180

Hide quick links: