Siemens Sinumerik 840D sl Function Manual page 775

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
C01714
Response
Acknowledgment
Explanation
Remedy
C01715
Response
Acknowledgment
Explanation
Remedy
C01745
Response
Acknowledgment
Explanation
Remedy
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
SI Motion P1 (CU): Safety limited speed exceeded
NONE
IMMEDIATELY (POWER ON)
The drive has moved faster than that specified by the speed limit value
(p9531). The drive is stopped by the configured stop response (p9563).
Message value (r9749, interpret as decimal):
100: SLS1 exceeded
200: SLS2 exceeded
300: SLS3 exceeded
400: SLS4 exceeded
1000: Encoder limit frequency exceeded.
Check the traversing program on the control.
-- Check the limits for (SLS) and if required, adapt (p9531).
This message can be acknowledged as follows:
-- Motion monitoring functions with SINUMERIK: From the machine
control panel
SI Motion P1 (CU): Safely limited position exceeded
NONE
IMMEDIATELY (POWER ON)
The axis has passed a parameterized position, which is monitored
using the "SLP" function.
Message value (r9749, interpret as decimal):
10: SLP1 violated
20: SLP2 violated
Check the traversing program on the control.
-- Check the limits for the SLP function and if required adapt (p9534,
p9535).
This message can be acknowledged as follows:
-- Motion monitoring functions with SINUMERIK: From the machine
control panel.
SI Motion P1 (CU): Check the braking torque for the brake test
NONE
IMMEDIATELY (POWER ON)
Parameter 2003 was used to change the scaling of the braking torque
for the braking test. A new acceptance test must be carried out for the
brake test. This identifies as to whether the brake test is still to be
carried out with the correct braking torque.
Carry out a power on for all components
-- Repeat the acceptance test for the safe brake test if the braking test
is used.
See also: p2003
10.3Safety messages for SINAMICS S120
Diagnostics
10-775

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents