Data Description
8.2 Parameters for SINAMICS S120
r9711[0...1]
SI Motion diagnostics results list 2
Display of result list 2, which led to an error between the two monitoring chan-
nels for a crosswise data comparison.
[0]: Result list second channel
[1]: Result list drive
Bit 00
actual value > upper limit SCA1+ (SN1+)
1 signal: Yes, 0 signal: No
Bit 01
actual value > lower limit SCA1+ (SN1+)
1 signal: Yes, 0 signal: No
Bit 02
actual value > upper limit SCA1- - (SN1- -)
1 signal: Yes, 0 signal: No
Bit 03
actual value > lower limit SCA1- - (SN1- -)
1 signal: Yes, 0 signal: No
Bit 04
actual value > upper limit SCA2+ (SN2+)
1 signal: Yes, 0 signal: No
Bit 05
actual value > lower limit SCA2+ (SN2+)
1 signal: Yes, 0 signal: No
Bit 06
actual value > upper limit SCA2- - (SN2- -)
1 signal: Yes, 0 signal: No
Bit 07
actual value > lower limit SCA2- - (SN2- -)
1 signal: Yes, 0 signal: No
Bit 08
actual value > upper limit SCA3+ (SN3+)
1 signal: Yes, 0 signal: No
Bit 09
actual value > lower limit SCA3+ (SN3+)
1 signal: Yes, 0 signal: No
Bit 10
actual value > upper limit SCA3- - (SN3- -)
1 signal: Yes, 0 signal: No
Bit 11
actual value > lower limit SCA3- - (SN3- -)
1 signal: Yes, 0 signal: No
Bit 12
actual value > upper limit SCA4+ (SN4+)
1 signal: Yes, 0 signal: No
Bit 13
actual value > lower limit SCA4+ (SN4+)
1 signal: Yes, 0 signal: No
Bit 14
actual value > upper limit SCA4- - (SN4- -)
1 signal: Yes, 0 signal: No
Bit 15
actual value > lower limit SCA4- - (SN4- -)
1 signal: Yes, 0 signal: No
Bit 16
actual value > upper limit SSM+ (n
1 signal: Yes, 0 signal: No
Bit 17
actual value > lower limit SSM+ (n
1 signal: Yes, 0 signal: No
Bit 18
actual value > upper limit SSM- - (n
1 signal: Yes, 0 signal: No
Bit 19
actual value > lower limit SSM- - (n
1 signal: Yes, 0 signal: No
Bit 20
actual value > upper limit modulo
1 signal: Yes, 0 signal: No
Bit 21
actual value > lower limit modulo
1 signal: Yes, 0 signal: No
See also: C01711
Unit:
Default value:
- -
- -
r9712
CO: SI Motion diagnostics position actual value motor side
Display of the actual position actual value on the motor side for the motion
monitoring functions on the Control Unit.
The display is updated in the safety monitoring cycle clock.
Unit:
Default value:
- -
- -
8-466
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
+)
x
+)
x
- -)
x
- -)
x
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Checksum:
Protection level:
No
3
Data type:
Effective:
Unsigned32
- -
Checksum:
Protection level:
3
No
Data type:
Effective:
Unsigned32
- -