10/15
r
Program
continuation
27202
Parameter
Explanation
Response
Remedy
Program
r
continuation
27203
Parameter
Explanation
Response
Remedy
Program
r
continuation
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
The alarm is initiated when booting. No program can be started. Only
clear the alarm with POWER ON.
PROFIsafe: MD %1[%2]: Address %3 error
%1 = MD name
%2 = MD field index
%3 = parameterized PROFIsafe address
The PROFIsafe address, parameterized in the specified MD is
incorrect. The value must be greater than 0.
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Correct the MD.
The alarm is initiated when booting. No program can be started. Only
clear the alarm with POWER ON.
PROFIsafe: MD %1[%2]: Incorrect SPL assignment
%1 = MD name
%2 = MD field index
The SPL coupling in the displayed MD is incorrect. Possible causes:
-- Bit value greater than in the definition of the SPL interface (bit value
>maximum bit value)
-- Number of bits higher than the number of bits per slot (upper bit
value -- lower bit value > 32)
-- Number of bits too high for this PROFIsafe module (upper bit value
-- lower bit value + 1> 8)
-- No SPL assignment was parameterized (both bit values are equal to
zero)
-- Incorrect SPL assignment (bit value equal to zero)
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Correct the displayed MD.
The alarm is initiated when booting. No program can be started. Only
clear the alarm with POWER ON.