Siemens Sinumerik 840D sl Function Manual page 381

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
13348
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
13349
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
13370
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
Only MD13370 $MN_SAFE_MODE_MASK = 0 is relevant for this documentation.
Please do not change this value.
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MN_SAFE_RDP_ERR_REAC[0...15]
Error response F_RECVDP
Min. input limit: 0
Protection level: 7/2
The error response defined here is initiated in the case of a communication error. This
value is valid as long as no other value is entered from the SPL via the system variable
$A_FRDP_ERR_REAC.
Meaning of values:
- - 0 = Alarm 27350 + Stop D/E
- - 1 = Alarm 27350
- - 2 = Alarm 27351 (display only, self clearing)
- - 3 = No system response
$MN_SAFE_RDP_SUBS[0...15]
Substitute values in the case of an error
Min. input limit: 0
Protection level: 7/2
In the case of a communication error, the substitute values defined here are activated in the
system variables $A_INSE assigned in this F_RECVDP- -SPL connection.
This value is valid as long as no other value is entered from the SPL via the system
variable $A_FRDP_SUBS.
$MN_SAFE_MODE
Safety operating mode
Min. input limit: 0
Protection level: 7/2
MD to distinguish between the safety operating modes:
0 = safety operating mode "SINUMERIK Safety Integrated (SPL)"
1 = safety operating mode "SINUMERIK Safety Integrated (drive- -based)"
2 = safety operating mode "SINUMERIK Safety Integrated (F_PLC) (without drive- -based)"
3 = safety operating mode "SINUMERIK Safety Integrated plus (F- -PLC)"
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: 3
Max. input limit: 0xFFFF
Max. input limit: 3
Data Description
Unit: - -
Unit: - -
Unit: - -
8-381