10/15
r9753[0...63]
SI message value for float values
Displays additional information about the safety message that has occurred for
float values.
See also r9744, r9747, r9748, p9752, r9754, r9755, r9756, p9759
Unit:
Default value:
- -
- -
r9754[0...63]
SI message time received in days
Displays the relative system runtime in days when the safety message
occurred.
See also r9744, r9747, r9748, r7949, p9752, r9753, r9755, r9756, p9759
Unit:
Default value:
days
- -
r9755[0...63]
SI message time removed in milliseconds
Displays the relative system runtime in milliseconds when the safety message
was removed.
See also r9744, r9747, r9748, r7949, p9752, r9753, r9754, r9756, p9759
Unit:
Default value:
ms
- -
r9756[0...63]
SI message time removed in days
Displays the relative system runtime in days when the safety message was
removed.
See also r9744, r9747, r9748, r7949, p9752, r9753,r9754, r9755, p9759
Unit:
Default value:
days
- -
p9761
SI password input
Enters the Safety Integrated password.
See also: F01659
It is not permissible to change Safety Integrated parameter settings until the
Safety Integrated password has been entered.
Unit:
Default value:
- -
0000 hex
p9762
SI new password
Enters a new Safety Integrated password.
If the Safety Integrated password is changed it must be acknowledged in the
following parameter:
See also: p9763
Unit:
Default value:
- -
0000 hex
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
- -
- -
Minimum value:
Maximum value:
0000 hex
FFFF FFFF hex
Minimum value:
Maximum value:
0000 hex
FFFF FFFF hex
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
- -
Data type:
Floating point
Checksum:
- -
Data type:
Unsigned16
Checksum:
- -
Data type:
Unsigned32
Checksum:
- -
Data type:
Unsigned16
Checksum:
No
Data type:
Unsigned32
Checksum:
No
Data type:
Unsigned32
Protection level:
3
Effective:
- -
Protection level:
3
Effective:
- -
Protection level:
3
Effective:
- -
Protection level:
3
Effective:
- -
Protection level:
3
Effective:
immediately
Protection level:
3
Effective:
immediately
8-473