Figure 7-24 Properties -- DP slave -- F configuration
By creating a new connection, the addresses for the net data and acknowledgment
telegram are automatically parameterized. The parameterized addresses should
then be entered in MD13334/13344 $MN_SAFE_SDP/RDP_LADDR.
7.4.2

Sender F_SENDDP

In order to send SPL output data ($A_OUTSE) from one SINUMERIK 840D sl to
another F--CPU using F_DP communication, an SPL connection must be para-
meterized. An SPL connection comprises the following:
S F_DP communication relationship
The parameters of the F_DP communication are defined using the F_DP
communication relationship:
-- Identifier (DP_DP_ID) and connection name
-- Communication parameters:
-- I/O start address (LADDR)
-- Monitoring time (TIMEOUT)
-- Error response (ERR_REAC)
S SPL coupling
The SPL coupling is used to define which SPL outputs ($A_OUTSE) are
mapped to which net data signals of the F telegram.
Note:
The interpretation and processing of the F net data signals are realized via the
PLC and NCK SPL and are the exclusive responsibility of the user or SPL pro-
grammer.
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
7.4 Safety- -related CPU- -CPU communication (F_DP communication)
Connecting Sensors/Actuators
7-245